Horner Logo
Search:      Select Region:  

HomeProductsSupportWhere to buyNews & EventsAbout usDownload
The OCS ConceptApplication Solutions
X SeriesClassic OCSHMI (TIU) ProductsI/O ProductsSoftwareCustomApplication Solutions
HelpdeskManualsCertificationOCS ProtocolsTIU ProtocolsApplication SolutionsMarketing Material
Distributer LocatorBecome a DistributorDistributer Centre
NewslettersMediaTradeshowsTrainingIn the News
ContactCompany ProfileHorner USATestimonialsCareersEnquiry Form
OCSTIUEnvisionServerMedia

  • Cscape
  • Firmware
  • Manuals
  • OCS Protocols
  • Sample applications



Cscape™ - Application for programming the whole range of OCSs

Please install this software before installing firmware file

Cscape Software
Description

Link

Version

Size

Release Notes

Cscape core application* zip_ico  Download

9.0

87.7 MB

pdf_ico Download

* Separate download required for firmware (available in next tab)

 

Cscape for Classic OCS
Description

Link

Version

Size

Cscape & Firmware bundle

zip_ico Download

8.1c

80.5 MB

Cscape core application*

zip_ico Download

8.1c

69.2 MB

* Separate download required for firmware (available in next tab)

 

NOTE: If you have previously downloaded and installed an earlier version of Cscape, uninstall that version before installing Cscape Version 8.80

This download is fully functional, but does not contain our extensive Symbol library, that contains thousands of easy to use graphics (complete symbol list available here). If you require the symbol library, please click the link below and have a All-in-one CD mailed to you.

Cscape Help Files - Newest version of Help Files considered as Cscape Manual

If you wish to have a CD mailed to you please click here



 


Firmware - specific to each hardware unit required by all OCSs

Now you can decide how to use our CAN port available on majority of OCS units:

  • CsCAN - protocol developed by Horner APG, guarantees easy peer-to-peer data exchange between all the nodes on the network (up to 255 nodes including OCS and SmartStix units). This is factory installed in each unit, can be updated by Cscape™ and is stored in the Cscape/Firmware directory
  • CANopen - wide known industry standard, supports up to 16 Slaves (when XLe or XLt as a Master) 127 Slaves (when XL6, NX or QX as a Master). By installing this firmware the CAN port will operate in the CANopen mode, replacing the factory installed CsCAN.



CsCAN / CANopen

X Series Firmware
Unit

Firmware version

Size

Release Notes/PUN†

XL6/Xl6e

zip_ico Version 12.62

3.0 MB

-

XLe/XLt

zip_ico Version 12.62

3.0 MB

-

QX (all models)

zip_ico Version 12.62

8.8 MB

-

NX

zip_ico Version 12.62

12.8 MB

-

LX (CsCAN only)

zip_ico Version 12.40

420 kB

pdf_ico Download

† Product Update Notes

Classic OCS Firmware
Unit

Firmware version

Size

All units

zip_ico Version 11.42

11.2 MB

 

 

 


Horner OCS Manuals

OCS
Cscape, X Series OCS, MiniOCS, MiniRCS, OCS1xx, OCS2xx, OCS250, and Color OCS, RCS2xx, SmartStack I/O, SmartStix CsCAN I/O, FOX I/O, VIM400, Wiring Accessories

Cscape Help Files

 


OCS protocols for Cscape™

Hot off the desktops from our development team are these X Series device protocols for use with our Cscape™ OCS programming software and XL Series, NX, LX and QX platforms.

To install, simply download the zipped files you require and extract the DLL inside to your Cscape/Protocols directory and restart Cscape™.

After extraction, the same directory (Cscape/Protocols) will hold a protocol specific help file in .chm format. The same file is accessible from Cscape menu -> Protocol Configuration -> Network -> 'Protocol Help' button.

ManufacturerProtocol
Allen BradleyDF1 (Micrologix, PLC5, SLC500)
AnimaticsSmartMotor
BaldorBaldor Serial
DanfossVLT5000 Series
ELMOSimpliq MC Protocol
Emerson Control TechniquesCTRTU
EurothermEurotherm 590/590+
EurothermEurotherm 635
FlowmaxFlowmax 400i
GE FANUCSeries 90(SNP)
GenericModbus Master
GenericModbus TCP/IP
GenericGPS (NMEA)
HornerCsCAN
IMOG7
IndramatSIS
KEBKEB Combivert
MitsubishiA Series
Mitsubishi FX Series
OmronOmron C Series
PMControlECmotor
SiemensPPI
SiemensUSS
ToshibaTosvert
ToshibaComputerLink

 

Protocols to be released in the near future:

  • YET (XtraDrive)
  • Ethernet ASCII


If you require more information or a protocol that is not listed please contact us to discuss development options.

 


Sample Applications

The following examples were created for the specific OCS platform. However they can be easily converted to fit any of the OCS platform specified in brackets. To do so one would have to make sure that the screens are properly formated (especially when converting from bigger to smaller screens).

 

 

Description

OCS platform

Required Version of Cscape (or later)

Link

XLe Standard Demo

XLe

8.60B

Download

XL6 Standard Demo

XL6

8.60B

Download

Datalogging example

QX (X-series)

8.60B

Download

XLt Standard Demo

XLt

8.60B

Download

Webserver Demo Software

NX, QX

8.60B

Download

LX Standard Demo

LX 300

8.60B

Download

NX Standard Demo

NX 25x

8.60B

Download

Stepper Application

XLe (XL-series)

8.60B

Download

SMS Send/Receive Demo

XLt (XL-series)

8.60B

Download

CANopen Demo (XLt & Wago IO)

XLt (X-series)

8.70B

Download

Smartmod Configuration App.

XLe (X-series)

8.60B

Download

Modbus Master Protocol example

XLt (XL-series)

8.60B

Download

Ethernet TCP/IP

XLt (XL-series)

8.60B

Download

GPRS Modbus Slave

XLt (XL-series)

8.60B

Download

 

Tab options

Home   |   Site Map   |   Contact   |   Privacy Policy   |   Company Information   |   © 2002-09 Horner APG