Don't want to use our New Concept in Control ?
For Users who prefer the Traditional arrangement of a PLC and Seperate Operator Interface. Horner offers the Remote Control Station (RCS) a feature packed Midrange Capable PLC at low end Prices.
CONTROL
The RCS has a ladder-based control engine that is powered by the highly-rated Intel 296 processor. This processor provides speed comparable to most mid-sized PLCs and is exactly the same as used in the OCS 100/200 family.
INPUT/OUTPUT
The SmartStack I/O expansion system allows the RCS to use both digital and analog I/O boards. Up to 4 I/O boards may be stacked onto a single RCS unit, giving you flexibility with various I/O combinations.
OPERATOR INTERFACE
Designed to be used with or without a seperate operator interface. Horner offers its TIU Range - a feature packed range of HMI that can be easily configured to communicate with the RCS.
NETWORKING
A benefit of the RCS is that it can connect to versions of the TIU that use our CAN based protocol CsCAN . This leaves the TIU with a Serial port free to communicate with a device of your choice.
When used with a fieldbus TIU on a Serial link the RCS can easily connect to popular Fieldbus networks.
Ethernet is also available via a Plug In Smartstack Module.
Cscape software provides graphical ladder diagram programming (IEC-1131 compliant) . Design engineers and end users will enjoy reduced development time with a straightforward approach to programming that integrates logic, and networking into a single solution operating in the Windows environments.
Relay Ladder Logic
While the RCS and Standard TIU is perfect for stand-alone applications, the true differentiator of the RCS is the integrated network. Standard with a CAN network port the RCS allows the user to choose between the industry standard DeviceNet slave protocol, or Horner's own true peer-to-peer protocol, CSCAN. Both offer high performance fieldbus networking.
DeviceNet is a master/slave protocol with limited peer-to-peer data exchange. The CsCAN protocol is optimized for peer-to-peer data, and is ideal for distributed control and data-collection applications. Using either protocol, OCS offers the ability to program, monitor, or debug any node on the network simply by having a serial connection at any location.
MINI RCS
Built on the miniOCS chassis and feature set, the miniRCS range offers first-rate performance for an affordable price.
All miniRCS units feature 64Kb of ladder logic memory, 8Kb of register memory, and one RS-232 serial port. MiniRCS units are available rith or without CAN network. The network may be configured for CsCAN or DeviceNet slave. When configured for the CsCAN network, SmartStix I/O is supported.
MiniRCS feature local I/O available in the same range of models as the miniOCS (tab Technical Specs).
RCS - Our PLC Expandable I/O Complete With Network
| Features | RCS210 |
|---|---|
| Display Characteristics | |
| Characters Per Page | No |
| Number of Pages | N/A |
| Graphic Pixels | N/A |
| Performance | |
| Logic Scan Time | 0.7ms/k of logic |
| Controller Functions | |
| Built In Logic Controller | Yes |
| Relay Ladder Logic Programming | Yes |
| PID AutoTuning | Yes |
| Serial Read/Write | Yes |
| Motion Commands | Yes |
| Floating Point Math | Yes |
| Graphics Supported | |
| Editable Graphics | No |
| Trending | No |
| Alarms and Status | Yes |
| Editable Fonts | No |
| Antimated Bit Maps | No |
| Graphing | No |
| Data Fields Per Page | N/A |
| Communications | |
| Serial Ports (RS-232) | One |
| Serial Ports (RS-232/RS-485) | No |
| Modbus RTU Master/Slave | Yes |
| CAN (CsCAN or DeviceNet Slave) | Yes |
| Ethernet | Yes (Smart Stack) |
| Memory | |
| Logic Memory | 64 kB |
| Graphic Memory | No |
| Text Screen Memory | 64 kB |
| Face Plate Options | |
| LEDs | No |
| Function Keys | No |
| System Keys | No |
| Numeric Keys | No |
| Hardware Specifications | |
| Operating Voltage | 10 to 30VDC |
| Specifications Smart Stack I/O Compatible | Yes |
| Real Time Clock | Yes |
| Environmental and Agency Standards | |
| Temperature Range (Operating/Storage) | 0 to 60C/-10 to 70C |
| Humidity (Non Condensing) | 5 to 95% |
| NEMA 4/12 IP 65 | Yes |
| NEMA 4/4X/12 | No |
| Agency Standards | UL Class 1 Div. II, C-UL, and CE |
| Physical Specifications | |
| Physical Dimensions | 146mm (5.75'') tall x 44.5mm (1.75'') wide x 98.4mm (3.87'') deep - SmartStack adds depth |
| Cut out Dimensions | N/A |
| Character Dimensions | N/A |
| Graphical Screen Dimensions | N/A |
| SmartStack Dimensions | 79.5mm (3.1'') tall x 19.1mm (0.75'') wide x 5.75mm (0.2'') deep |
| Communications Options | Ethernet |
| Speed | 10Meg |
| Number of Drops | Unlimited |
| Distance | Unlimited |
| Programming over network | Yes |
| Peer to Peer | Yes |
| Global Data | Yes |
| Data Grams | Yes |
| Ethernet Global Data | Yes |
| Modbus RTU Master/Slave | N/A |
| Modems | N/A |
| Fiber Optics | Yes |
Cscape - OCS Programming Software
SmartMod : Our newest OCS I/O option, SmartMod I/O, is now available to expand your OCS system.
SmartStix : SmartStix I/O is a new terminal-block style I/O for the Operator Control Station.
SmartStack : SmartStack I/O expansion system allows the flexibility of using digital, analog and specialty I/O boards.
FOX I/O (when using HE800FOX100) : The SmartStack Fiber Optic Expansion (FOX) Base extends a high-speed OCS back plane enabling METAL SmartStack I/O Modules to be mounted several meters from the OCS
Wiring accessories : Wiring accessories that are available for the use with Operator Control Station (OCS) products to provide users with flexible wiring options